A Rare Case of Retrieval of Level IIIc Fractured Copper Intrauterine Device: A

Authors

  • Nikita Vijay
  • Suraj Sable
  • Anuja Bhalerao

Keywords:

Copper T(CuT), Intra uterine device, removal of fractured IUD, hysteroscope, case report

Abstract


Intrauterine devices (IUDs), both hormonal and non-hormonal, are among the several forms of contraception.  Reports of IUD fragments being retained in the intrauterine wall have been noticed and these results highlight the significance of the need to remove IUD carefully by the healthcare professionals.  A married 36-year-old woman, P2L2, visited the outpatient department with complaint of pain abdomen. History reveals that a copper IUD was inserted seven years ago postpartum at the time of the patient's second delivery and breakage of CuT threads 2 months back. Initial per speculum examination showed a mild erosion of posterior lip of cervix and inflammatory change on Pap smear. Fragmented CuT embedded in myometrium was diagnosed and confirmed on transvaginal USG and pelvic radiograph which was ultimately extracted with a resectoscope using USG guided hysteroscopy.   Practitioners who handle IUD insertion and removal should be aware of this atypical complication.  There should be improved communication between healthcare providers and patients regarding the risk of fracture IUD.  The significance of meticulous IUD planning, from insertion to removal, is highlighted in this case study.

Downloads

Download data is not yet available.

References

[1] Ambadekar NN, Rathod KZ, Zodpey SP. Study of Cu T utilization status and some of the factors associated with discontinuation of Cu T in rural part of Yavatmal District. Indian J Community Med 2011;36(1):54-6.

[2] Ministry of Health and Family Welfare. IUCD Reference Manual for Medical Officers. Family Planning Division Ministry of Health and Family Welfare Government of India July 2007.

[3] Bliss Kaneshiro and Tod Aeby. Long-term safety, efficacy, and patient acceptability of the intrauterine Copper T-380A contraceptive device. International Journal of Women’s Health 2010; 2:211–220.

[4] Dubovis M, Rizk N. Retained copper fragments following removal of a copper intrauterine device: two case reports, Case Rep. Womens Health 2020; e00208.

[5] Irving Sivin. Utility and drawbacks of continuous use of a copper T IUD for 20 years, Contraception 2007;75(6):S70-S75.

[6] S. Wilson, G. Tan, M. Baylson, C. Schreiber, Controversies in family planning: how to manage a fractured IUD, Contraception 88 (5) (2013) 599–603.

[7] Fernandez CM, Cabiya MA, Levine EM, Granberry K, Locher S. The “Broken” IUD: Its detection and clinical management. Open J Clin Med Case Rep 2015;1(9):1049.

[8] Howard B, Grubb E, Lage MJ, Tang B. Trends in use of and complications from intrauterine contraceptive devices and tubal ligation or occlusion. Reprod Health. 2017 Jun 8;14(1):70.

[9] Johnson BA. Insertion and removal of intrauterine devices. Am. Fam. Physician 2005;71(1):95–102.

[10] Wakrim S, Lahlou L. Spontaneously expelled IUD and missing fragments in the uterine cavity. Radiol Case Rep 2020;15(9):1654–1656.

[11] Wildemeersch D, Hasskamp T and Goldstuck ND. Malposition and displacement of intrauterine devices–diagnosis, management and prevention. Clin Obstet Gynecol Reprod Med 2016; 2(3): 183-188.

[12] Latack KR, Nguyen BT. Trends in copper versus hormonal intrauterine device breakage reporting within the United States’ Food and Drug Administration Adverse Event Reporting System, Contraception 2023;118:109909.

[13] Vitale SG, Di Spiezio Sardo A, Riemma G et al. In office hysteroscopic removal of retained or fragmented intrauterine device without anesthesia: a cross sectional analysis of an international survey. Springer Updates in Surgery 2022; 74:1079–1085.

[14] Burks CA et al. Hysteroscopic Retrieval of a Fractured Intrauterine IUD. Journal of Minimally Invasive Gynecology.2014;21(6):S54.

[15] Townsend L, Luxford E and Mizia K. Effectiveness of ultrasound- guided removal of intrauterine devices. Aust N Z J Obstet Gynaecol 2022; 62: 800–802

Downloads

Published

2026-01-07

How to Cite

1.
Vijay N, Sable S, Bhalerao A. A Rare Case of Retrieval of Level IIIc Fractured Copper Intrauterine Device: A. J Neonatal Surg [Internet]. 2026 Jan. 7 [cited 2026 Jan. 20];14(33S):397-402. Available from: https://jneonatalsurg.com/index.php/jns/article/view/9838