Rehabilitation Of Patient with Mandibular Denture Using Extracoronal Semiprecision Attachment Combined with Custom-Made Non-Rigid Connector – A Case Report

Authors

  • Dr Maria Jenifer Sabita F X
  • Srishti Relan
  • Sushma S G
  • Chinmayi
  • Rohit Kundu
  • Kedar

Keywords:

Extracoronal attachments, combined prosthesis, Removable partial denture, Semi precision attachments, Distal extension denture, Non-rigid connector

Abstract

The restoration of a partially edentulous arch can be a great challenge when there is a Kennedy’s class I or class II situation with unilateral or bilateral posterior teeth that are completely missing. It all the more becomes challenging in a long span fixed partial denture scenario where the forces would be substantial to the remaining abutment teeth. Successful restoration can be done with various conventional and contemporary treatment options. One such treatment modality is extracoronal semi-precision attachment retained cast partial dentures combined with a stress breaker for the long span fixed partial denture. This article describes a case report with mandibular Kennedy’s class 1 modification 2 partially edentulous arch rehabilitated with a cast partial denture having an extracoronal semi precision attachment (RHEIN 83 attachment system) and a customized non-rigid connector using pen refill.

Downloads

Download data is not yet available.

Metrics

Metrics Loading ...

References

Patil A, Sethi T, Doddamani MH, Shah R, Patil AG, Vora A, Dave T, Joshi D. Split It! Let’s Break That Stress-A Case Report. Journal of Evolution of Medical and Dental Sciences. 2021 Jun 7;10(23):1803-7.

Rani P, Malhotra P. Breaking the stress with a non-rigid connector. Nigerian Postgraduate Medical Journal. 2020 Oct 1;27(4):391-3.

Shillingburg HT Jr., Hobo S, Whitsett LD, Jacobi R, Brackett SE. Fundamentals of Fixed Prosthodontics. Chicago: Quintessence; 1997. p. 531-2.

Yaqoob A, Rasheed N, Ashraf J, Yaqub G. Nonrigid semi-precision connectors for FPD. Dentistry and Medical Research. 2014 Jan 1;2(1):17-21.

Preiskel HW. Precision Attachments in Dentistry. London: Henry Kimpton; 1968.pp.16-21.

Shillinburg HT,Jr,Sather DA, Wilson EL, Cain JR, Mitchell DL, Blanco LJ, et al. Vol 4. Chicago: Quintessecnce; 2012. Fundamental of Fixed Prosthodontics; pp. 91-2.

Mishra A, Palaskar J, Madhav VN, Chopade SR. Pier Abutment : Break the stress. Ann Prsthod Rest Dent. 2016;2:126-8.

Rosenstiel SF, Land MF, Fujimoto J. 4th ed. ST Louis: Mosby Elsevier Inc.; 2006. Contemporary Fixed Prosthodontics; pp. 673-93.

Sreedevi K, Anulekha CK, Gudapati B. Smile Design with Customized Non-rigid Connector as Stress Breaker!!--A Case Report. Journal homepage: www. nacd. in Indian J Dent Adv. 2023 Apr 1;13(2):74-8.

Goodacre CJ, Bernal G, Rungcharassaeng K, Kan JY. Clinical complications in fixed prosthodontics. The Journal of prosthetic dentistry. 2003 Jul 1;90(1):31-41.

Downloads

Published

2025-06-18

How to Cite

1.
Sabita F X DMJ, Relan S, S G S, Chinmayi C, Kundu R, Kedar K. Rehabilitation Of Patient with Mandibular Denture Using Extracoronal Semiprecision Attachment Combined with Custom-Made Non-Rigid Connector – A Case Report. J Neonatal Surg [Internet]. 2025Jun.18 [cited 2025Jul.10];14(32S):769-75. Available from: https://jneonatalsurg.com/index.php/jns/article/view/7450

Similar Articles

You may also start an advanced similarity search for this article.